− | |message_desc=??? | + | |message_desc=A 1D pit object can be connected to a maximum of wjs??? 2D cells. |
− | |suggestions= | + | |suggestions=Change number of cells pit is connected to using the Conn_No attribute in the 1d_nwk layer. If a '''very''' large pit object is modelled which requires connection to more 2D cell than the maximum a '''SX''' boundary can be manually specified in a 2d_bc layer, this gives the user control over the cells connected to the pit. |
|discussion_page=* [[Talk:TUFLOW Message 2215|Discuss Message 2215]] | |discussion_page=* [[Talk:TUFLOW Message 2215|Discuss Message 2215]] | ||
|link3='' | |link3='' |
Revision as of 12:09, 18 February 2011
TUFLOW Message
WARNING 2215 - Exceeded limit of 2D cells connected to 1D pit object.
Alternate Message
NA
Message Type
WARNING
Description
A 1D pit object can be connected to a maximum of wjs??? 2D cells.
Suggestions
Change number of cells pit is connected to using the Conn_No attribute in the 1d_nwk layer. If a very large pit object is modelled which requires connection to more 2D cell than the maximum a SX boundary can be manually specified in a 2d_bc layer, this gives the user control over the cells connected to the pit.