TUFLOW Message 2306: Difference between revisions
Jump to navigation
Jump to search
Content deleted Content added
No edit summary |
Extra information on 0 WrF for older versions |
||
Line 1: | Line 1: | ||
{{TUFLOW_Message |
{{TUFLOW_Message |
||
|tuflow_message=ERROR 2306 - WrF value must be greater than zero |
|tuflow_message=ERROR 2306 - WrF value must be greater than zero. |
||
|alt_msg=NA |
|alt_msg=NA |
||
|type=[[ERROR]] |
|type=[[ERROR]] |
||
|message_desc=Occurs when a WrF (Weir calibration factor for upstream controlled weir flow) of zero has been found. |
|message_desc=Occurs when a WrF (Weir calibration factor for upstream controlled weir flow) of zero has been found. For "<tt>Wetting and Drying == ON Method B</tt>" which has been the default method since 2012-05 a non zero WrF must be specified. For "<tt>Wetting and Drying == ON</tt>" or "<tt>Defaults == Pre 2012</tt>" a zero value could be used to locally turn off the weir function. |
||
|suggestions=Check for zero values that may have been inadvertently applied using one or a combination of the following commands: |
|suggestions=Check for zero values that may have been inadvertently applied using one or a combination of the following commands: <tt>Read GIS WrF==, Set WrF==, Read RowCol WrF==</tt>. |
||
|discussion_page=* [[Talk:TUFLOW Message 2306|Discuss Message 2306]] |
|discussion_page=* [[Talk:TUFLOW Message 2306|Discuss Message 2306]] |
||
|link3='' |
|link3='' |
Revision as of 11:54, 14 February 2018
TUFLOW Message
ERROR 2306 - WrF value must be greater than zero.
Alternate Message
NA
Message Type
ERROR
Description
Occurs when a WrF (Weir calibration factor for upstream controlled weir flow) of zero has been found. For "Wetting and Drying == ON Method B" which has been the default method since 2012-05 a non zero WrF must be specified. For "Wetting and Drying == ON" or "Defaults == Pre 2012" a zero value could be used to locally turn off the weir function.
Suggestions
Check for zero values that may have been inadvertently applied using one or a combination of the following commands: Read GIS WrF==, Set WrF==, Read RowCol WrF==.