(Created page with "{{TUFLOW_Message |tuflow_message=ERROR 3037: Cell area factors must be >= 0.0001. <br> |alt_msg=None |type=ERROR |message_desc=The value of specified Storage Reduction...")
 
Line 6: Line 6:
 
|type=[[ERROR]]  
 
|type=[[ERROR]]  
 
|message_desc=The value of specified Storage Reduction Factor must be greater than 0.0001 (0.01%).  
 
|message_desc=The value of specified Storage Reduction Factor must be greater than 0.0001 (0.01%).  
|suggestions=
+
|suggestions=The Storage Reduction Factor (SRF) can be used to reduce the storage of 2D cells (for example to model hypothetical filling, or reduced storage from buildings).  It is a reduction factor, so if a cell has a SRF value of 0.1, then its storage (surface area) is reduced by 10%.
  
 
|discussion_page=* [[Talk:TUFLOW Message 3037|Discuss Message 3037]]
 
|discussion_page=* [[Talk:TUFLOW Message 3037|Discuss Message 3037]]

Revision as of 10:21, 20 April 2018

TUFLOW Message
ERROR 3037: Cell area factors must be >= 0.0001.

Alternate Message
None

Message Type
ERROR

Description
The value of specified Storage Reduction Factor must be greater than 0.0001 (0.01%).

Suggestions
The Storage Reduction Factor (SRF) can be used to reduce the storage of 2D cells (for example to model hypothetical filling, or reduced storage from buildings). It is a reduction factor, so if a cell has a SRF value of 0.1, then its storage (surface area) is reduced by 10%.


Up
Go-up.png 3xxx Messages