TUFLOW Message 2011: Difference between revisions
Content deleted Content added
Created page with '{{TUFLOW_Message |tuflow_message=???? |message_desc=Not Used. |suggestions=???? |discussion_page=* Discuss Message 2011 |link3='' |link4='' |prelink=...' |
No edit summary |
||
Line 1:
{{TUFLOW_Message
|tuflow_message=ERROR 2011 - Using Mat command when no materials file has been specified.
|alt_msg=NA
|type=[[ERROR]]
|message_desc=A .tgc materials command such as Set Mat == or Read GIS Mat == has been specified, but Read Materials File == in the .tcf file has not been specified. A materials file must be specified if .tgc Mat commands are used. <br>
|discussion_page=* [[Talk:TUFLOW Message 2011|Discuss Message 2011]]▼
This ERROR was introduced in Build 2010-10-AC. Prior to Build 2010-10-AC, if no materials file was specified a default Manning's n value of 0.05 is used. The 2d_uvpt_check layer can be used to validate the Manning's n values assigned to the model after all inputs.<br>
|link3=''
|link4=''
|prelink=[[TUFLOW_Message_2010|Message 2010]]
|uplink=[[2xxx_TUFLOW_Messages|2xxx Messages]]
|nextlink=[[TUFLOW_Message_2012|Message 2012]]
}}
| |||