Difference between revisions of "TUFLOW Message 2011"
Jump to navigation
Jump to search
Line 3: | Line 3: | ||
|alt_msg=NA | |alt_msg=NA | ||
|type=[[ERROR]] | |type=[[ERROR]] | ||
− | |message_desc=A .tgc materials command such as Set Mat ==, Read GIS Mat == or Read RowCol Grid == has been specified, but Read Materials File == in the .tcf file has not been specified. A materials file must be specified if .tgc Mat commands are used. <br> | + | |message_desc=A .tgc materials command such as "Set Mat ==", "Read GIS Mat ==", "Read RowCol Mat ==" or "Read RowCol Grid ==" has been specified, but "Read Materials File ==" in the .tcf file has not been specified. A materials file must be specified if .tgc Mat commands are used. <br> |
This ERROR was introduced in Build 2010-10-AC. Prior to Build 2010-10-AC, if no materials file was specified a default Manning's n value of 0.05 is used. The 2d_uvpt_check layer can be used to validate the Manning's n values assigned to the model after all inputs.<br> | This ERROR was introduced in Build 2010-10-AC. Prior to Build 2010-10-AC, if no materials file was specified a default Manning's n value of 0.05 is used. The 2d_uvpt_check layer can be used to validate the Manning's n values assigned to the model after all inputs.<br> |
Revision as of 10:59, 12 April 2011
TUFLOW Message
ERROR 2011 - Using Mat command when no materials file has been specified.
Alternate Message
NA
Message Type
ERROR
Description
A .tgc materials command such as "Set Mat ==", "Read GIS Mat ==", "Read RowCol Mat ==" or "Read RowCol Grid ==" has been specified, but "Read Materials File ==" in the .tcf file has not been specified. A materials file must be specified if .tgc Mat commands are used.
This ERROR was introduced in Build 2010-10-AC. Prior to Build 2010-10-AC, if no materials file was specified a default Manning's n value of 0.05 is used. The 2d_uvpt_check layer can be used to validate the Manning's n values assigned to the model after all inputs.
Suggestions
{{{suggestions}}}
Up |
---|
2xxx Messages |