|suggestions=Check number of HT boundaries in the 2d_bc layer and consider modification if more than 253. Check number of HT boundaries read in the model by searching for "nht" in the .tlf file. If the number is higher than number of HT boundaries in the 2d_bc layer check if attribute Td, A and/or B has a value specified.
 
 
 
|discussion_page=* [[Talk:TUFLOW Message 3022|Discuss Message 3022]]
 
|discussion_page=* [[Talk:TUFLOW Message 3022|Discuss Message 3022]]
 
|link3=''
 
|link3=''

Revision as of 09:24, 11 July 2018

TUFLOW Message
ERROR 3022: Number of Boundary Level Graphs exceeded. Maximum is 253.

Alternate Message
None

Message Type
ERROR

Description
HPC has a limit of 253 unique HT boundaries.

Suggestions
Check number of HT boundaries in the 2d_bc layer and consider modification if more than 253. Check number of HT boundaries read in the model by searching for "nht" in the .tlf file. If the number is higher than number of HT boundaries in the 2d_bc layer check if attribute Td, A and/or B has a value specified.