TUFLOW Message 1527: Difference between revisions
Jump to navigation
Jump to search
Content deleted Content added
Steph.dufour (talk | contribs) No edit summary |
No edit summary |
||
| Line 10: | Line 10: | ||
|prelink=[[TUFLOW_Message_1522|Message 1522]] |
|prelink=[[TUFLOW_Message_1522|Message 1522]] |
||
|uplink=[[1xxx_TUFLOW_Messages|1xxx Messages]] |
|uplink=[[1xxx_TUFLOW_Messages|1xxx Messages]] |
||
|nextlink=[[ |
|nextlink=[[TUFLOW_Message_1621|Message 1621]] |
||
}} |
}} |
||
Revision as of 16:43, 8 August 2018
TUFLOW Message
ERROR 1527 - Could not find Operating Control Definition for Channel 'a'.
Alternate Message
NA
Message Type
ERROR
Description
The channel 'a' is a structure, pump or other device that is to be controlled by operating rules (denoted by adding the optional flag 'O' to the 1d_nwk type). The rules associated with channel 'a' cannot be found.
Suggestions
Ensure that a <control_id> has been entered for the Inlet_Type attribute within the 1d_nwk object for channel 'a'. Check that a Operating Controls .toc file has been created and “Define Control ==”…“End Define” logic blocks have been specified for <Control_id>. Note that more than one channel can reference the same operational control logic.
| Up |
|---|