Difference between revisions of "TUFLOW Message 2215"
Jump to navigation
Jump to search
Line 3: | Line 3: | ||
|alt_msg=NA | |alt_msg=NA | ||
|type=[[WARNING]] | |type=[[WARNING]] | ||
− | |message_desc=A 1D pit object can be connected to a maximum of | + | |message_desc=A 1D pit object can be connected to a maximum of 10 2D cells. |
|suggestions=Change number of cells pit is connected to using the Conn_No attribute in the 1d_nwk layer. If a '''very''' large pit object is modelled which requires connection to more 2D cell than the maximum a '''SX''' boundary can be manually specified in a 2d_bc layer, this gives the user control over the cells connected to the pit. | |suggestions=Change number of cells pit is connected to using the Conn_No attribute in the 1d_nwk layer. If a '''very''' large pit object is modelled which requires connection to more 2D cell than the maximum a '''SX''' boundary can be manually specified in a 2d_bc layer, this gives the user control over the cells connected to the pit. | ||
|discussion_page=* [[Talk:TUFLOW Message 2215|Discuss Message 2215]] | |discussion_page=* [[Talk:TUFLOW Message 2215|Discuss Message 2215]] |
Revision as of 15:21, 21 August 2018
TUFLOW Message
WARNING 2215 - Exceeded limit of 2D cells connected to 1D pit object.
Alternate Message
NA
Message Type
WARNING
Description
A 1D pit object can be connected to a maximum of 10 2D cells.
Suggestions
Change number of cells pit is connected to using the Conn_No attribute in the 1d_nwk layer. If a very large pit object is modelled which requires connection to more 2D cell than the maximum a SX boundary can be manually specified in a 2d_bc layer, this gives the user control over the cells connected to the pit.
Up |
---|
2xxx Messages |