TUFLOW Message 2044: Difference between revisions
Content deleted Content added
Steph.dufour (talk | contribs) No edit summary |
No edit summary |
||
Line 3:
|alt_msg=WARNING 2044 - 2D HX cell ZC level is below 1D bed level. <br> WARNING 2044 - ZC level of ",a," at 2D HX cell is below interpolated node bed level of
|type=[[ERROR]] <br> [[WARNING]]
|message_desc=The ground level of the 2D cell (ZC level) is below the 1D bed level. 2D cells selected by 1D/2D (HX) interface lines must be at or above the bed level of the 1D channel. This error usually occurs when the 1D/2D interface line (HX line) passes through a depression that is lower than the bed levels of the 1D cross-sections.<br>
The linking method when using 2D HX boundaries is described here:
[[Tutorial_Module04#1D.2F2D_Links | Tutorial module 4, 1d/2d links]]<br>
| |||