|alt_msg=ERROR 2043 - Flow from 2D HX cell has been assigned to an ISIS non-RIVER unit. Flows from 2D HX cells can only be assigned to ISIS RIVER units.<BR> |
|alt_msg=ERROR 2043 - Flow from 2D HX cell has been assigned to an ISIS non-RIVER unit. Flows from 2D HX cells can only be assigned to ISIS RIVER units.<BR> |
||
WARNING 2043 - 2D HX cell has been assigned to an ISIS non-RIVER unit. |
WARNING 2043 - 2D HX cell has been assigned to an ISIS non-RIVER unit. |
||
|type=[[ERROR]] |
|type=[[ERROR]]<br> |
||
[[WARNING]] |
[[WARNING]] |
||
|message_desc=2D HX cell has been assigned to an ISIS non-RIVER unit. Only ISIS RIVER units or INTERPOLATE units may be connected to a 2D HX boundary in a linked ISIS-TUFLOW model. |
|message_desc=2D HX cell has been assigned to an ISIS non-RIVER unit. Only ISIS RIVER units or INTERPOLATE units may be connected to a 2D HX boundary in a linked ISIS-TUFLOW model. |
||
Revision as of 16:52, 18 October 2018
TUFLOW Message
ERROR 2043 - 2D HX cell has been assigned to an ISIS non-RIVER unit.
Alternate Message
ERROR 2043 - Flow from 2D HX cell has been assigned to an ISIS non-RIVER unit. Flows from 2D HX cells can only be assigned to ISIS RIVER units.
WARNING 2043 - 2D HX cell has been assigned to an ISIS non-RIVER unit.
Description
2D HX cell has been assigned to an ISIS non-RIVER unit. Only ISIS RIVER units or INTERPOLATE units may be connected to a 2D HX boundary in a linked ISIS-TUFLOW model.
Suggestions
Check the node type within the ISIS .dat file and remove connection (CN) lines within the 2d_bc layer at any non-RIVER/INTERPOLATE units.
Since TUFLOW built 2018-03-AC this error can be changed into warning by using command SX FMP Unit Type Error == OFF.