TUFLOW Message 1625: Difference between revisions
Jump to navigation
Jump to search
Content deleted Content added
No edit summary |
No edit summary |
||
| Line 1: | Line 1: | ||
{{TUFLOW_Message |
{{TUFLOW_Message |
||
|tuflow_message=CHECK 1625 - Unconnected pit |
|tuflow_message=CHECK 1625 - Unconnected pit |
||
|alt_msg=CHECK 1625 - Could not find any channel ends for Pit XXX. 1D virtual pipe connection assumed. To treat as an ERROR use PIT NO 1D CONNECTION == ERROR. |
|||
|alt_msg=NA |
|||
|type=[[CHECK]] |
|type=[[CHECK]] |
||
|message_desc=Pit is not snapped or within the <font color="blue"><tt>Pit Search Distance </tt></font> <font color="red"><tt>==</tt></font>. |
|message_desc=Pit is not snapped or within the <font color="blue"><tt>Pit Search Distance </tt></font> <font color="red"><tt>==</tt></font>, and will be modelled as an 1D virtual pipe. |
||
|suggestions=If the pit must be connected to a 1D channel, use the ECF command <font color="blue"><tt>Pit No 1D Connection </tt></font> <font color="red"><tt>==</tt></font> ERROR to force an error and check the pit connection. See also [[TUFLOW_Message_1626|ERROR 1626]]. |
|||
|suggestions=Check the pit connection. See also [[Talk:TUFLOW Message 1625|Discuss Message 1625]]. |
|||
|discussion_page=* |
|discussion_page=*[[Talk:TUFLOW Message 1625|Discuss Message 1625]] |
||
|link3='' |
|link3='' |
||
|link4='' |
|link4='' |
||
Revision as of 11:52, 2 January 2019
TUFLOW Message
CHECK 1625 - Unconnected pit
Alternate Message
CHECK 1625 - Could not find any channel ends for Pit XXX. 1D virtual pipe connection assumed. To treat as an ERROR use PIT NO 1D CONNECTION == ERROR.
Message Type
CHECK
Description
Pit is not snapped or within the Pit Search Distance ==, and will be modelled as an 1D virtual pipe.
Suggestions
If the pit must be connected to a 1D channel, use the ECF command Pit No 1D Connection == ERROR to force an error and check the pit connection. See also ERROR 1626.
| Up |
|---|