Difference between revisions of "TUFLOW Message 1625"
Jump to navigation
Jump to search
Line 1: | Line 1: | ||
{{TUFLOW_Message | {{TUFLOW_Message | ||
− | |tuflow_message=CHECK 1625 - Unconnected pit | + | |tuflow_message=CHECK 1625 - Unconnected pit. |
|alt_msg=CHECK 1625 - Could not find any channel ends for Pit XXX. 1D virtual pipe connection assumed. To treat as an ERROR use PIT NO 1D CONNECTION == ERROR. | |alt_msg=CHECK 1625 - Could not find any channel ends for Pit XXX. 1D virtual pipe connection assumed. To treat as an ERROR use PIT NO 1D CONNECTION == ERROR. | ||
|type=[[CHECK]] | |type=[[CHECK]] |
Revision as of 14:34, 2 January 2019
TUFLOW Message
CHECK 1625 - Unconnected pit.
Alternate Message
CHECK 1625 - Could not find any channel ends for Pit XXX. 1D virtual pipe connection assumed. To treat as an ERROR use PIT NO 1D CONNECTION == ERROR.
Message Type
CHECK
Description
Pit is not snapped or within the Pit Search Distance ==, and will be modelled as an 1D virtual pipe.
Suggestions
If the pit must be connected to a 1D channel, use the ECF command Pit No 1D Connection == ERROR to force an error and check the pit connection. See also ERROR 1626.