Difference between revisions of "TUFLOW Message 0036"

From Tuflow
Jump to navigation Jump to search
Line 3: Line 3:
 
|alt_msg=NA
 
|alt_msg=NA
 
|type=[[ERROR]]
 
|type=[[ERROR]]
|message_desc=????
+
|message_desc=If using the new event management feature introduced in the 2010-10 release, the old approach of using <font color="green"><tt>BC Event Name == </tt></font>cannot be used.
|suggestions=????
+
|suggestions=Review approach to defining and managing events and use either the <font color="green"><tt>BC Event Name == </tt></font> command or the event management options introduced in the 2010-10 release.
 
|discussion_page=* [[Talk:TUFLOW Message 0036|Discuss Message 0036]]
 
|discussion_page=* [[Talk:TUFLOW Message 0036|Discuss Message 0036]]
 
|link3=''
 
|link3=''

Revision as of 11:07, 10 August 2011

TUFLOW Message
ERROR 0036 - Cannot use ""BC Event Name =="" if using -e option or ""Model Events =="".

Alternate Message
NA

Message Type
ERROR

Description
If using the new event management feature introduced in the 2010-10 release, the old approach of using BC Event Name == cannot be used.

Suggestions
Review approach to defining and managing events and use either the BC Event Name == command or the event management options introduced in the 2010-10 release.