Difference between revisions of "TUFLOW Message 1095"
Jump to navigation
Jump to search
Line 1: | Line 1: | ||
{{TUFLOW_Message | {{TUFLOW_Message | ||
− | |tuflow_message=ERROR 1095 - Reading 1d_ta attribute data from .mid file line below: | + | |tuflow_message=ERROR 1095 - Reading 1d_ta attribute data from .mid file line below: Check that the new format introduced in 2003-03-AA is used. "","xz","","","","","","","", 0.000000000000000, 0.000000000000000 |
|alt_msg=NA | |alt_msg=NA | ||
|type=[[ERROR]] | |type=[[ERROR]] |
Revision as of 10:51, 7 March 2019
TUFLOW Message
ERROR 1095 - Reading 1d_ta attribute data from .mid file line below: Check that the new format introduced in 2003-03-AA is used. "","xz","","","","","","","", 0.000000000000000, 0.000000000000000
Alternate Message
NA
Message Type
ERROR
Description
The 1d_ta / 1d_xs does not have the correct attribute data.
Suggestions
Check the attributes by opening the .mif file in a text editor, columns 5:18 should look like the below:
Columns 12
Source Char(50)
Type Char(2)
Flags Char(8)
Column_1 Char(20)
Column_2 Char(20)
Column_3 Char(20)
Column_4 Char(20)
Column_5 Char(20)
Column_6 Char(20)
Z_Increment Float
Z_Maximum Float
Skew Float
Data
Up |
---|
1xxx Messages |