Line 3: | Line 3: | ||
|alt_msg=ERROR 2441 - 2D VG boundaries not yet supported for HPC Solver. | |alt_msg=ERROR 2441 - 2D VG boundaries not yet supported for HPC Solver. | ||
|type=[[ERROR]] | |type=[[ERROR]] | ||
− | |message_desc=The stage-discharge (HQ) boundaries are not available in earlier TUFLOW | + | |message_desc=The stage-discharge (HQ) boundaries are not available in earlier TUFLOW GPU versions. The 2D VG boundaries not yet supported for HPC Solver. |
− | |suggestions=Use the latest TUFLOW release or the HQ boundary will need to be replaced with a HT boundary. If the water level is at ground level or below, normal flow is applied at the boundary. For functionality of 2D VG boundaries consider using TUFLOW Classic or variable Z shapes in HPC. | + | |suggestions=Use the latest TUFLOW HPC release or the HQ boundary will need to be replaced with a HT boundary. If the water level is at ground level or below, normal flow is applied at the boundary. For functionality of 2D VG boundaries consider using TUFLOW Classic or variable Z shapes in TUFLOW HPC. |
|discussion_page=* [[Talk:TUFLOW Message 2441|Discuss Message 2441]] | |discussion_page=* [[Talk:TUFLOW Message 2441|Discuss Message 2441]] | ||
|link3='' | |link3='' |
Revision as of 09:43, 21 April 2020
TUFLOW Message
ERROR 2441 - HQ boundaries not yet supported for GPU Solver.
Alternate Message
ERROR 2441 - 2D VG boundaries not yet supported for HPC Solver.
Message Type
ERROR
Description
The stage-discharge (HQ) boundaries are not available in earlier TUFLOW GPU versions. The 2D VG boundaries not yet supported for HPC Solver.
Suggestions
Use the latest TUFLOW HPC release or the HQ boundary will need to be replaced with a HT boundary. If the water level is at ground level or below, normal flow is applied at the boundary. For functionality of 2D VG boundaries consider using TUFLOW Classic or variable Z shapes in TUFLOW HPC.