Difference between revisions of "TUFLOW Message 3525"
Jump to navigation
Jump to search
Line 11: | Line 11: | ||
|prelink=[[TUFLOW_Message_3522|Message 3522]] | |prelink=[[TUFLOW_Message_3522|Message 3522]] | ||
|uplink=[[3xxx_TUFLOW_Messages|3xxx Messages]] | |uplink=[[3xxx_TUFLOW_Messages|3xxx Messages]] | ||
− | |nextlink=[[ | + | |nextlink=[[TUFLOW_Message_3526|Message 3526]] |
}} | }} |
Revision as of 16:03, 31 August 2020
TUFLOW Message
WARNING 3525: Potentially SLOW SGS processing of grid using the double precision version of TUFLOW.
Alternate Message
N/A
Message Type
WARNING
Description
Due to an Intel Compiler issue this grid inspection has to be done with un-optimised code and will be slow. Note HPC solver does not generally require double precision engine. If XF files are enabled (default), subsequent initialisations will be much faster.
Suggestions
Consider whether double precision is needed in the project or allow for longer initialisation time.
Up |
---|
3xxx Messages |