TUFLOW Message 1521: Difference between revisions

From Tuflow
Jump to navigation Jump to search
Content deleted Content added
Created page with "{{TUFLOW_Message |tuflow_message=ERROR 1521 - Could not identify 2D active cell in any 2D domain at coordinates 'x', 'y'. for operating control variable 'a' in line below. Op..."
 
No edit summary
Line 3: Line 3:
|alt_msg=NA
|alt_msg=NA
|type=[[ERROR]]
|type=[[ERROR]]
|message_desc=????
|message_desc=Operating control feature is outside of 2D active cell.
|suggestions=Check the operating control feature location. If grid_check file doesn't exist, add "Verbose == ON" to the .tcf file to get written pre-processing layers/grids.
|suggestions=????
|discussion_page=* [[Talk:TUFLOW Message 1521|Discuss Message 1521]]
|discussion_page=* [[Talk:TUFLOW Message 1521|Discuss Message 1521]]
|link3=''
|link3=''

Revision as of 10:31, 15 September 2020

TUFLOW Message
ERROR 1521 - Could not identify 2D active cell in any 2D domain at coordinates 'x', 'y'. for operating control variable 'a' in line below. Operating Control Line = 'a' == 'b'

Alternate Message
NA

Message Type
ERROR

Description
Operating control feature is outside of 2D active cell.

Suggestions
Check the operating control feature location. If grid_check file doesn't exist, add "Verbose == ON" to the .tcf file to get written pre-processing layers/grids.


Up
1xxx Messages