Difference between revisions of "TUFLOW Message 1423"

From Tuflow
Jump to navigation Jump to search
(Created page with "{{TUFLOW_Message |tuflow_message=ERROR 1423 - Virtual Pit occurs at the same location as a user defined node, manhole or a pit IDs: <channel ids> |alt_msg=N/A |type=ERROR...")
 
Line 4: Line 4:
 
|type=[[ERROR]]
 
|type=[[ERROR]]
 
|message_desc=Virtual Pit outlet cannot be connected to the same location as a user defined node, manhole or a pit.
 
|message_desc=Virtual Pit outlet cannot be connected to the same location as a user defined node, manhole or a pit.
|suggestions=Consider connection by upstream or downstream end of the channel instead.
+
|suggestions=Consider connection by upstream or downstream end of the channel instead. Virtual pits need to be read in before 1d_nwk if they are discharging into 1D channels.
 
|discussion_page=* [[Talk:TUFLOW Message 1423|Discuss Message 1423]]
 
|discussion_page=* [[Talk:TUFLOW Message 1423|Discuss Message 1423]]
 
|link3=''
 
|link3=''

Revision as of 10:53, 18 December 2020

TUFLOW Message
ERROR 1423 - Virtual Pit occurs at the same location as a user defined node, manhole or a pit IDs: <channel ids>

Alternate Message
N/A

Message Type
ERROR

Description
Virtual Pit outlet cannot be connected to the same location as a user defined node, manhole or a pit.

Suggestions
Consider connection by upstream or downstream end of the channel instead. Virtual pits need to be read in before 1d_nwk if they are discharging into 1D channels.


Up
Go-up.png 1xxx Messages