InfoWorks ICM to TUFLOW: Difference between revisions
Content deleted Content added
Tuflowduncan (talk | contribs) |
Tuflowduncan (talk | contribs) |
||
Line 48:
|'''1D Pipes''' ||Conduit||1d_nwk_pipe||Conduit shape ‘CIRC’ are set as Type ‘C’ and shape ‘RECT’ are set as type ‘R’, otherwise the conduit shape is set to I. Where ‘I’, the shape will need separately defining. Conduit Width/Height are converted from ‘mm’ to ‘m’. Manning's n roughness value are copied if roughness type is 'N'.
|-
|'''1D Subcatchment''' ||Subcatchment||1d_sa_subcatchment||Only the Geometry is exported.
|-
|rowspan="15" | '''1D Structures''' ||Bridge||1d_nwk_Bridges||Bridge methods are different so the bridge would need to be rebuilt in TUFLOW/Estry. Only the link geometry is exported.
Line 66:
| Irregular Weir||1d_nwk_Irregular_Weir||Imported as an irregular weir. Section data needs bringing across.
|-
| Orifice||1d_nwk_Orifice||Geometry Exported but no direct equivalent in TUFLOW currently..
|-
| Pump||1d_nwk_Pump||Geometry Exported. Set as a PO type but user should check and add Operational Control
|-
| Screen||1d_nwk_Screen||Geometry Exported but no direct equivalent in TUFLOW currently.
|-
| Siphon||1d_nwk_Siphon||Geometry Exported but no direct equivalent in TUFLOW currently.
|-
| Sluice||1d_nwk_Sluices||Geometry Exported.
| |||