Line 6:
 
The reason for this is that <font color="green"><tt>BC Database </tt></font> can be specified any number of times, with the most recent occurrence being used to set the active database when a <font color="green"><tt>Read GIS BC </tt></font> command occurs. This was used by modellers as a way of applying different events or probabilities to different boundaries. If using the 2010-10 release or later, it is recommended to switch to the new event management feature as this is much more flexible and intuitive (see Section 4.12 in the 2010-10 TUFLOW Manual).
This error can occur if bc_dbase is listed under a scenario/event block, but incorrect scenario/event is specified and the simulation runs without bc_dbase.
|suggestions=Check the <font color="green"><tt>BC Database </tt></font>command occurs before any <font color="green"><tt>Read GIS BC </tt></font> commands. If there is no <font color="green"><tt>BC Database </tt></font>command one will need to be specified (unless there are no boundaries, ie. no <font color="green"><tt>Read GIS BC </tt></font> commands).
|discussion_page=* [[Talk:TUFLOW Message 0100|Discuss Message 0100]]