Difference between revisions of "TUFLOW Message 1527"
Jump to navigation
Jump to search
Line 10: | Line 10: | ||
|prelink=[[TUFLOW_Message_1522|Message 1522]] | |prelink=[[TUFLOW_Message_1522|Message 1522]] | ||
|uplink=[[1xxx_TUFLOW_Messages|1xxx Messages]] | |uplink=[[1xxx_TUFLOW_Messages|1xxx Messages]] | ||
− | |nextlink=[[ | + | |nextlink=[[TUFLOW_Message_1619|Message 1619]] |
}} | }} |
Revision as of 08:39, 5 May 2022
TUFLOW Message
ERROR 1527 - Could not find Operating Control Definition for Channel 'a'.
Alternate Message
NA
Message Type
ERROR
Description
The channel 'a' is a structure, pump or other device that is to be controlled by operating rules (denoted by adding the optional flag 'O' to the 1d_nwk type). The rules associated with channel 'a' cannot be found.
Suggestions
Ensure that a <control_id> has been entered for the Inlet_Type attribute within the 1d_nwk object for channel 'a'. Check that a Operating Controls .toc file has been created and Define Control == … End Define logic blocks have been specified for <Control_id>. Note that more than one channel can reference the same operational control logic.
Up |
---|
1xxx Messages |