Difference between revisions of "TUFLOW Message 1381"

From Tuflow
Jump to navigation Jump to search
Line 3: Line 3:
 
|alt_msg=NA
 
|alt_msg=NA
 
|type=[[WARNING]]
 
|type=[[WARNING]]
|message_desc=The default manhole coefficient used for the Engelhund approach is greater than 1. For C manholes the <tt>Manhole Default C Exit Coefficient == </tt> is applied, and for R manholes <tt>Manhole Default R Exit Coefficient == </tt>is used.  The defaults for C and R exit coefficients are 0.25 and 0.5 respectively.
+
|message_desc=The default manhole coefficient used for the Engelhund approach is greater than 1. For C manholes the <tt><font color="blue">Manhole Default C Exit Coefficient </font><font color="red">== </font></tt> is applied, and for R manholes <tt><font color="blue">Manhole Default R Exit Coefficient </font><font color="red">== </font></tt>is used.  The defaults for C and R exit coefficients are 0.25 and 0.5 respectively.
 
|suggestions=Default is outside normal ranges, review data and modify is appropriate.
 
|suggestions=Default is outside normal ranges, review data and modify is appropriate.
 
|discussion_page=* [[Talk:TUFLOW Message 1381|Discuss Message 1381]]
 
|discussion_page=* [[Talk:TUFLOW Message 1381|Discuss Message 1381]]

Revision as of 16:57, 23 June 2022

TUFLOW Message
WARNING 1381 - Manhole Default Exit Coefficient is greater than 1.

Alternate Message
NA

Message Type
WARNING

Description
The default manhole coefficient used for the Engelhund approach is greater than 1. For C manholes the Manhole Default C Exit Coefficient == is applied, and for R manholes Manhole Default R Exit Coefficient == is used. The defaults for C and R exit coefficients are 0.25 and 0.5 respectively.

Suggestions
Default is outside normal ranges, review data and modify is appropriate.


Up