Difference between revisions of "TUFLOW Message 1031"
Line 10: | Line 10: | ||
If the water level lines have only 2 vertices (no nodes on the lines, only a start and an end), then the line must go from 2d_bc to 2d_bc and '''cross''' the 1D network.<br> | If the water level lines have only 2 vertices (no nodes on the lines, only a start and an end), then the line must go from 2d_bc to 2d_bc and '''cross''' the 1D network.<br> | ||
If the water level line have 3 or more vertices, then the line must go from 2d_bc to 2d_bc and '''snap''' to the 1D network. <br> | If the water level line have 3 or more vertices, then the line must go from 2d_bc to 2d_bc and '''snap''' to the 1D network. <br> | ||
− | Should you need further information on configuring water level lines, refer to [http://wiki.tuflow.com/index.php?title=Tutorial_Module04#Review_the_Results Tutorial Model 4] | + | Should you need further information on configuring water level lines, refer to <u>[http://wiki.tuflow.com/index.php?title=Tutorial_Module04#Review_the_Results Tutorial Model 4]</u> |
− | + | ||
− | |||
− | |||
|prelink=[[TUFLOW_Message_1030|Message 1030]] | |prelink=[[TUFLOW_Message_1030|Message 1030]] | ||
|uplink=[[1xxx_TUFLOW_Messages|1xxx Messages]] | |uplink=[[1xxx_TUFLOW_Messages|1xxx Messages]] | ||
|nextlink=[[TUFLOW_Message_1032|Message 1032]] | |nextlink=[[TUFLOW_Message_1032|Message 1032]] | ||
}} | }} |
Revision as of 15:54, 1 July 2022
TUFLOW Message
ERROR 1031 - End of a WLL cannot snap to 1D node
Alternate Message
ERROR 1031 - End of a WLL cannot snap to a 1D channel
Message Type
ERROR
Description
This error indicates that there is a configuration problem with the 1d_wll and 1d_nwk layers
Suggestions
Load the messages, 1d_wll, 1d_nwk and 2d_bc layers into your GIS package. Using the messages layer, locate the area where the error occurs.
Check that the water level lines are configured correctly.
Remember:
Water level lines should go left to right looking downstream.
If the water level lines have only 2 vertices (no nodes on the lines, only a start and an end), then the line must go from 2d_bc to 2d_bc and cross the 1D network.
If the water level line have 3 or more vertices, then the line must go from 2d_bc to 2d_bc and snap to the 1D network.
Should you need further information on configuring water level lines, refer to Tutorial Model 4
Up |
---|