Specify inverts upstream and downstream of the culvert, either via the US_invert / DS_invert in the 1D channel object or via snapped 1D node objects. | Specify inverts upstream and downstream of the culvert, either via the US_invert / DS_invert in the 1D channel object or via snapped 1D node objects. | ||
− | + | ||
− | |||
− | |||
|prelink=[[TUFLOW_Message_1037|Message 1037]] | |prelink=[[TUFLOW_Message_1037|Message 1037]] | ||
|uplink=[[1xxx_TUFLOW_Messages|1xxx Messages]] | |uplink=[[1xxx_TUFLOW_Messages|1xxx Messages]] | ||
|nextlink=[[TUFLOW_Message_1042|Message 1042]] | |nextlink=[[TUFLOW_Message_1042|Message 1042]] | ||
}} | }} |
Revision as of 15:56, 1 July 2022
TUFLOW Message
ERROR 1041 - Culvert branch splits downstream of channel ",a," at Node ",a,". Could not interpolate invert.
Alternate Message
ERROR 1041 - Culvert branch splits upstream of channel ",a," at Node ",a,". Could not interpolate invert.
Message Type
ERROR
Description
Multiple upstream or downstream channel, unable to interpolate inverts.
Suggestions
A useful tip at a junction of 1D channels is to use a connector (Channel_Type of “X”) for connecting a side tributary or pipe into the main flowpath. TUFLOW will then be able to interpolate inverts.