TUFLOW Message 1104: Difference between revisions
Jump to navigation
Jump to search
Content deleted Content added
No edit summary |
No edit summary |
||
| Line 5: | Line 5: | ||
|message_desc=Diameter for circular culvert (C type channel) is less than or equal to zero. |
|message_desc=Diameter for circular culvert (C type channel) is less than or equal to zero. |
||
|suggestions=Ensure that the Width_or_Dia (14th filed) GIS attribute is greater than 0. This diameter is in metres, not mm! |
|suggestions=Ensure that the Width_or_Dia (14th filed) GIS attribute is greater than 0. This diameter is in metres, not mm! |
||
|discussion_page=* [[Talk:TUFLOW Message 1104|Discuss Message 1104]] |
|||
|link3='' |
|||
|link4='' |
|||
|prelink=[[TUFLOW_Message_1103|Message 1103]] |
|prelink=[[TUFLOW_Message_1103|Message 1103]] |
||
|uplink=[[1xxx_TUFLOW_Messages|1xxx Messages]] |
|uplink=[[1xxx_TUFLOW_Messages|1xxx Messages]] |
||
Revision as of 16:34, 1 July 2022
TUFLOW Message
ERROR 1104 - Diameter of C culvert is less than or equal to zero.
Alternate Message
NA
Message Type
ERROR
Description
Diameter for circular culvert (C type channel) is less than or equal to zero.
Suggestions
Ensure that the Width_or_Dia (14th filed) GIS attribute is greater than 0. This diameter is in metres, not mm!