The default is 0.002m (2mm) or 0.007ft if using Units == US Customary. The depth should be selected according to the magnitude of flooding depths. For broad-scale models with large cell sizes values of up to 0.05m (0.16ft) have typically been used, while for models using the direct rainfall approach, or that have a high proportion of steep flow, a wet/dry depth of less than a mm (eg. 0.0002m or 0.0007ft) may be required due to the substantial amount of shallow sheet flow. A reduced wet/dry depth of 0.0002m (0.0007ft) is particularly recommended for direct rainfall models. | The default is 0.002m (2mm) or 0.007ft if using Units == US Customary. The depth should be selected according to the magnitude of flooding depths. For broad-scale models with large cell sizes values of up to 0.05m (0.16ft) have typically been used, while for models using the direct rainfall approach, or that have a high proportion of steep flow, a wet/dry depth of less than a mm (eg. 0.0002m or 0.0007ft) may be required due to the substantial amount of shallow sheet flow. A reduced wet/dry depth of 0.0002m (0.0007ft) is particularly recommended for direct rainfall models. | ||
− | + | ||
− | |||
− | |||
|prelink=[[TUFLOW_Message_3006|Message 3006]] | |prelink=[[TUFLOW_Message_3006|Message 3006]] | ||
|uplink=[[3xxx_TUFLOW_Messages|3xxx Messages]] | |uplink=[[3xxx_TUFLOW_Messages|3xxx Messages]] | ||
|nextlink=[[TUFLOW_Message_3008|Message 3008]] | |nextlink=[[TUFLOW_Message_3008|Message 3008]] | ||
}} | }} |
Revision as of 16:45, 1 July 2022
TUFLOW Message
ERROR 3007: Wet/dry depth threshold must be >= 0.0001.
Alternate Message
none
Message Type
ERROR
Description
The wet/dry depth threshold has been set to a value below the minimum allowed.
Suggestions
Ensure that the value specified with the "Cell Wet/Dry Depth" tcf command is a depth > 0.0001m.
The default is 0.002m (2mm) or 0.007ft if using Units == US Customary. The depth should be selected according to the magnitude of flooding depths. For broad-scale models with large cell sizes values of up to 0.05m (0.16ft) have typically been used, while for models using the direct rainfall approach, or that have a high proportion of steep flow, a wet/dry depth of less than a mm (eg. 0.0002m or 0.0007ft) may be required due to the substantial amount of shallow sheet flow. A reduced wet/dry depth of 0.0002m (0.0007ft) is particularly recommended for direct rainfall models.