TUFLOW Message 3010: Difference between revisions

Content deleted Content added
No edit summary
No edit summary
Line 9:
The minimum permissible target timestep allowed for the HPC Solver is set with the 'Timestep Minimum' TCF command, where the default is the minimum of 0.1 seconds or the cell size divided by 200 m/s. This value must be less than the initial timestep value specified for the HPC Solver with the 'Timestep' or 'Timestep Intitial' TCF commands. The timestep can also not be less than 0.000001s.
 
 
|discussion_page=* [[Talk:TUFLOW Message 3010|Discuss Message 3010]]
|link3=''
|link4=''
|prelink=[[TUFLOW_Message_3009|Message 3009]]
|uplink=[[3xxx_TUFLOW_Messages|3xxx Messages]]