TUFLOW Message 3036: Difference between revisions
Content deleted Content added
No edit summary |
No edit summary |
||
Line 7:
|message_desc=Hydrographs were not accepted by the HPC solver. Prior to 2020-10-AA release this error was caused by multiplication factors f1 and f2 in the 2d_rf layer other than 1.
|suggestions=Use the latest TUFLOW release. If multiplication factors other than 1 are used and TUFLOW version cannot be updated, multiplication should be applied to the source hydrographs rather than the factors f1 and f2.<br>
If the above doesn't apply, please contact <u>[mailto:support@tuflow.com support@tuflow.com]</u>.
|discussion_page=* [[Talk:TUFLOW Message 3036|Discuss Message 3036]]
| |||