Difference between revisions of "TUFLOW Message 1178"
Line 5: | Line 5: | ||
|message_desc=An error has occurred whilst reading 1d network data (1d_nwk). This may occur if the attribute types in the file do not match what TUFLOW is expecting for a 1d_nwk command. | |message_desc=An error has occurred whilst reading 1d network data (1d_nwk). This may occur if the attribute types in the file do not match what TUFLOW is expecting for a 1d_nwk command. | ||
|suggestions= Aways use an empty 1d_nwk template file as the GIS entry for 1d_nwk inputs. DO NOT create empty 1d_nwk template files mannually yourself. Use either TCF command, <tt><font color="blue">Write Empty MI Files </font><font color="red">== </font></tt> or <tt><font color="blue">Write Empty SHP Files </font><font color="red">== </font></tt> to create these template files. Also, ensure the layer has the correct attributes and ensure that the <tt><font color="blue">Read GIS Network </font><font color="red">== </font></tt> command is only used for network data, not 1D boundary or table links. | |suggestions= Aways use an empty 1d_nwk template file as the GIS entry for 1d_nwk inputs. DO NOT create empty 1d_nwk template files mannually yourself. Use either TCF command, <tt><font color="blue">Write Empty MI Files </font><font color="red">== </font></tt> or <tt><font color="blue">Write Empty SHP Files </font><font color="red">== </font></tt> to create these template files. Also, ensure the layer has the correct attributes and ensure that the <tt><font color="blue">Read GIS Network </font><font color="red">== </font></tt> command is only used for network data, not 1D boundary or table links. | ||
− | + | ||
− | |||
− | |||
|prelink=[[TUFLOW_Message_1177|Message 1177]] | |prelink=[[TUFLOW_Message_1177|Message 1177]] | ||
|uplink=[[1xxx_TUFLOW_Messages|1xxx Messages]] | |uplink=[[1xxx_TUFLOW_Messages|1xxx Messages]] | ||
|nextlink=[[TUFLOW_Message_1179|Message 1179]] | |nextlink=[[TUFLOW_Message_1179|Message 1179]] | ||
}} | }} |
Revision as of 13:56, 5 July 2022
TUFLOW Message
ERROR 1178 - Reading channel network data. Check 1d_nwk layer has correct attributes.
Alternate Message
NA
Message Type
ERROR
Description
An error has occurred whilst reading 1d network data (1d_nwk). This may occur if the attribute types in the file do not match what TUFLOW is expecting for a 1d_nwk command.
Suggestions
Aways use an empty 1d_nwk template file as the GIS entry for 1d_nwk inputs. DO NOT create empty 1d_nwk template files mannually yourself. Use either TCF command, Write Empty MI Files == or Write Empty SHP Files == to create these template files. Also, ensure the layer has the correct attributes and ensure that the Read GIS Network == command is only used for network data, not 1D boundary or table links.