Revision as of 14:00, 5 July 2022
TUFLOW Message
ERROR 1205 - Invalid loss method specified for Manhole.
Alternate Message
NA
Message Type
ERROR
Description
Invalid loss approach defined in the Loss_Approach attribute for 1d_mh layer. Valid options are:
“NO” for no manhole loss approach (the standard entry/exit losses of the connected culverts applies).
“EN” for the Engelhund loss approach.
“FX” for the Fixed loss approach.
If left blank, the global default type set by Manhole Default Loss Approach == ecf command is used.
Suggestions
Specify a valid loss approach.