Line 8: Line 8:
|suggestions=Set the 'UCS' attribute to 'T' in the 1D network layer or manually assign storage via a "NA" table. For missing CS data, ensure that a cross-section has been correctly specified.<br>
|suggestions=Set the 'UCS' attribute to 'T' in the 1D network layer or manually assign storage via a "NA" table. For missing CS data, ensure that a cross-section has been correctly specified.<br>
If this error occurs at a node or pit location, ensure that this is correctly snapped to a channel.
If this error occurs at a node or pit location, ensure that this is correctly snapped to a channel.

|discussion_page=* [[Talk:TUFLOW Message 1353|Discuss Message 1353]]
|link3=''
|link4=''
|prelink=[[TUFLOW_Message_1352|Message 1352]]
|prelink=[[TUFLOW_Message_1352|Message 1352]]
|uplink=[[1xxx_TUFLOW_Messages|1xxx Messages]]
|uplink=[[1xxx_TUFLOW_Messages|1xxx Messages]]

Revision as of 15:43, 5 July 2022

TUFLOW Message
ERROR 1353 - No NA data for Node <Node ID>

Alternate Message
ERROR 1353 - No CS data for Chan <Chan ID>

Message Type
ERROR

Description
If the message is "No NA data for Node" TUFLOW has encountered a 1D Node with no storage allocation. This typically occurs if the 'UCS' (use channel storage) attribute in a 1D network layer is set to 'F' (false).
If the message is "No CS data for Chan" no cross-sectional information has been provided for channel.
This error can also occur if you have a pit or node object, which is not correctly snapped to a channel.

Suggestions
Set the 'UCS' attribute to 'T' in the 1D network layer or manually assign storage via a "NA" table. For missing CS data, ensure that a cross-section has been correctly specified.
If this error occurs at a node or pit location, ensure that this is correctly snapped to a channel.