Difference between revisions of "TUFLOW Message 1391"

From Tuflow
Jump to navigation Jump to search
Line 7: Line 7:
 
You can link two or more TUFLOW nodes to the same external 1D node by connecting the TUFLOW nodes (ie. snap them or use a connector (X) channel), and link to the external node.
 
You can link two or more TUFLOW nodes to the same external 1D node by connecting the TUFLOW nodes (ie. snap them or use a connector (X) channel), and link to the external node.
 
|suggestions=Review connections to external 1D scheme for this node and remove the inappropriate one(s).
 
|suggestions=Review connections to external 1D scheme for this node and remove the inappropriate one(s).
|discussion_page=* [[Talk:TUFLOW Message 1391|Discuss Message 1391]]
+
 
|link3=''
 
|link4=''
 
 
|prelink=[[TUFLOW_Message_1382|Message 1382]]
 
|prelink=[[TUFLOW_Message_1382|Message 1382]]
 
|uplink=[[1xxx_TUFLOW_Messages|1xxx Messages]]
 
|uplink=[[1xxx_TUFLOW_Messages|1xxx Messages]]
 
|nextlink=[[TUFLOW_Message_1392|Message 1392]]
 
|nextlink=[[TUFLOW_Message_1392|Message 1392]]
 
}}
 
}}

Revision as of 15:45, 5 July 2022

TUFLOW Message
ERROR 1391 - Cannot connect Node with a X1DH or X1DQ link as the node is already connected to an external 1D domain via a X1DH or X1DQ link.

Alternate Message
NA

Message Type
ERROR

Description
A TUFLOW 1D (ESTRY) node is trying to be connected to an external 1D scheme using a X1DH or X1DQ link as indicated in the message, but the TUFLOW node is already connected to an external 1D node using a link as indicated in the message. Only one external 1D scheme link can be specified for a TUFLOW (ESTRY) node.

You can link two or more TUFLOW nodes to the same external 1D node by connecting the TUFLOW nodes (ie. snap them or use a connector (X) channel), and link to the external node.

Suggestions
Review connections to external 1D scheme for this node and remove the inappropriate one(s).


Up
Go-up.png 1xxx Messages