TUFLOW Message
ERROR 2001 - 2d_bc object is outside 2D model domain
Alternate Message
ERROR 2001 - GIS Object is outside 2D model domain
WARNING 2001 - ",a," "object" at ",a,",",a," is outside 2D model domain
Description
An object is located outside the 2D domain that it is assigned to. The Check Inside Grid == command controls whether this message is an ERROR, WARNING or not given.
Suggestions
The _messages_P.shp or _messages.mif layer in the log folder contains the locations of the offending boundary objects. Review the _dom_check file and the messages layer to ensure that all 2d_bc objects are within the model domain.
Check that the projection of the boundary layer is the same as the TUFLOW model projection.