Difference between revisions of "TUFLOW Message 2011"

From Tuflow
Jump to navigation Jump to search
Line 7: Line 7:
 
This ERROR was introduced in Build 2010-10-AC.  Prior to Build 2010-10-AC, if no materials file was specified a default Manning's n value of 0.05 is used.  The 2d_uvpt_check layer can be used to validate the Manning's n values assigned to the model after all inputs.<br>
 
This ERROR was introduced in Build 2010-10-AC.  Prior to Build 2010-10-AC, if no materials file was specified a default Manning's n value of 0.05 is used.  The 2d_uvpt_check layer can be used to validate the Manning's n values assigned to the model after all inputs.<br>
 
|suggestions=Check that your <u>'''.tcf'''</u> (not .tgc) file contains a "<font color="blue"><tt>Read Materials File </tt></font><font color="red"><tt>==</tt></font> " command.
 
|suggestions=Check that your <u>'''.tcf'''</u> (not .tgc) file contains a "<font color="blue"><tt>Read Materials File </tt></font><font color="red"><tt>==</tt></font> " command.
|discussion_page=* [[Talk:TUFLOW Message 2010|Discuss Message 2010]]
+
 
|link3=''
 
|link4=''
 
 
|prelink=[[TUFLOW_Message_2010|Message 2010]]
 
|prelink=[[TUFLOW_Message_2010|Message 2010]]
 
|uplink=[[2xxx_TUFLOW_Messages|2xxx Messages]]
 
|uplink=[[2xxx_TUFLOW_Messages|2xxx Messages]]
 
|nextlink=[[TUFLOW_Message_2012|Message 2012]]
 
|nextlink=[[TUFLOW_Message_2012|Message 2012]]
 
}}
 
}}

Revision as of 15:54, 5 July 2022

TUFLOW Message
ERROR 2011 - Using Mat command when no materials file has been specified.

Alternate Message
NA

Message Type
ERROR

Description
A .tgc materials command such as "Set Mat ==", "Read GIS Mat ==", "Read RowCol Mat ==" or "Read RowCol Grid ==" has been specified, but "Read Materials File ==" in the .tcf file has not been specified. A materials file must be specified if .tgc Mat commands are used.

This ERROR was introduced in Build 2010-10-AC. Prior to Build 2010-10-AC, if no materials file was specified a default Manning's n value of 0.05 is used. The 2d_uvpt_check layer can be used to validate the Manning's n values assigned to the model after all inputs.

Suggestions
Check that your .tcf (not .tgc) file contains a "Read Materials File == " command.


Up
Go-up.png 2xxx Messages