TUFLOW Message 2029: Difference between revisions

From Tuflow
Jump to navigation Jump to search
Content deleted Content added
No edit summary
No edit summary
Line 5: Line 5:
|message_desc=2D SH/SC connection must be to a cell in the same 2D domain.
|message_desc=2D SH/SC connection must be to a cell in the same 2D domain.
|suggestions=Flow versus head (SH) boundary condition must connect via SC object to a 2D cell in same 2D model domain or to 1D node. This type of boundary is used to model the pumping of water from one location to another.
|suggestions=Flow versus head (SH) boundary condition must connect via SC object to a 2D cell in same 2D model domain or to 1D node. This type of boundary is used to model the pumping of water from one location to another.

|discussion_page=* [[Talk:TUFLOW Message 2029|Discuss Message 2029]]
|link3=''
|link4=''
|prelink=[[TUFLOW_Message_2028|Message 2028]]
|prelink=[[TUFLOW_Message_2028|Message 2028]]
|uplink=[[2xxx_TUFLOW_Messages|2xxx Messages]]
|uplink=[[2xxx_TUFLOW_Messages|2xxx Messages]]

Revision as of 16:04, 5 July 2022

TUFLOW Message
ERROR 2029 - 2D SH/SC connection must be to a cell in the same 2D domain.

Alternate Message
NA

Message Type
ERROR

Description
2D SH/SC connection must be to a cell in the same 2D domain.

Suggestions
Flow versus head (SH) boundary condition must connect via SC object to a 2D cell in same 2D model domain or to 1D node. This type of boundary is used to model the pumping of water from one location to another.


Up
2xxx Messages