Difference between revisions of "TUFLOW Message 2085"

From Tuflow
Jump to navigation Jump to search
Line 7: Line 7:
 
<font color="blue"><tt>Bed Resistance Cell Sides </tt></font><font color="red"><tt>== </tt></font><font color="black"><tt>INTERROGATE</tt></font> is the default in the TUFLOW (as of TUFLOW Build 2007-07-AA), applies the exact value from the material polygons at each cell side. With the <font color="blue"><tt>Read MID</tt></font> commands a value is inputted for each cell and value at cell side calculated using either average n, average M (1/n) or maximum n.  The two approaches are therefore incompatible.
 
<font color="blue"><tt>Bed Resistance Cell Sides </tt></font><font color="red"><tt>== </tt></font><font color="black"><tt>INTERROGATE</tt></font> is the default in the TUFLOW (as of TUFLOW Build 2007-07-AA), applies the exact value from the material polygons at each cell side. With the <font color="blue"><tt>Read MID</tt></font> commands a value is inputted for each cell and value at cell side calculated using either average n, average M (1/n) or maximum n.  The two approaches are therefore incompatible.
 
|suggestions=Specify an interpolation method for cell sides (<font color="blue"><tt>Bed Resistance Cell Sides </tt></font><font color="red"><tt>== </tt></font>) if using <font color="blue"><tt>Read MID</tt></font> commands to define roughness.  Or use GIS inputs (<font color="blue"><tt>Read GIS MAT or FRIC </tt></font><font color="red"><tt>== </tt></font> ) with <font color="blue"><tt>Bed Resistance Cell Sides </tt></font><font color="red"><tt>== </tt></font><font color="black"><tt>INTERROGATE</tt></font>.
 
|suggestions=Specify an interpolation method for cell sides (<font color="blue"><tt>Bed Resistance Cell Sides </tt></font><font color="red"><tt>== </tt></font>) if using <font color="blue"><tt>Read MID</tt></font> commands to define roughness.  Or use GIS inputs (<font color="blue"><tt>Read GIS MAT or FRIC </tt></font><font color="red"><tt>== </tt></font> ) with <font color="blue"><tt>Bed Resistance Cell Sides </tt></font><font color="red"><tt>== </tt></font><font color="black"><tt>INTERROGATE</tt></font>.
|discussion_page=* [[Talk:TUFLOW Message 2085|Discuss Message 2085]]
+
 
|link3=''
 
|link4=''
 
 
|prelink=[[TUFLOW_Message_2084|Message 2084]]
 
|prelink=[[TUFLOW_Message_2084|Message 2084]]
 
|uplink=[[2xxx_TUFLOW_Messages|2xxx Messages]]
 
|uplink=[[2xxx_TUFLOW_Messages|2xxx Messages]]
 
|nextlink=[[TUFLOW_Message_2086|Message 2086]]
 
|nextlink=[[TUFLOW_Message_2086|Message 2086]]
 
}}
 
}}

Revision as of 13:18, 6 July 2022

TUFLOW Message
ERROR 2085 - Read MID Mat or Read MID CnM cannot be used with Bed Resistance Cell Sides == INTERROGATE

Alternate Message
ERROR 2085 - Read MID Grid command cannot be used with Bed Resistance Cell Sides == INTERROGATE

Message Type
ERROR

Description
Read MID Mat, Read MID CnM or Read MID Grid .tgc commands cannot be used with Bed Resistance Cell Sides == INTERROGATE .tcf command. Specify Bed Resistance Cell Sides == AVERAGE n or Bed Resistance Cell Sides == AVERAGE M or Bed Resistance Cell Sides == MAXIMUM n in the .tcf file.

Bed Resistance Cell Sides == INTERROGATE is the default in the TUFLOW (as of TUFLOW Build 2007-07-AA), applies the exact value from the material polygons at each cell side. With the Read MID commands a value is inputted for each cell and value at cell side calculated using either average n, average M (1/n) or maximum n. The two approaches are therefore incompatible.

Suggestions
Specify an interpolation method for cell sides (Bed Resistance Cell Sides == ) if using Read MID commands to define roughness. Or use GIS inputs (Read GIS MAT or FRIC == ) with Bed Resistance Cell Sides == INTERROGATE.


Up
Go-up.png 2xxx Messages