Difference between revisions of "TUFLOW Message 2215"
Jump to navigation
Jump to search
Line 5: | Line 5: | ||
|message_desc=A 1D pit object can be connected to a maximum of 10 2D cells. | |message_desc=A 1D pit object can be connected to a maximum of 10 2D cells. | ||
|suggestions=Change number of cells pit is connected to using the Conn_No attribute in the 1d_nwk layer. If a '''very''' large pit object is modelled which requires connection to more 2D cell than the maximum a '''SX''' boundary can be manually specified in a 2d_bc layer, this gives the user control over the cells connected to the pit. | |suggestions=Change number of cells pit is connected to using the Conn_No attribute in the 1d_nwk layer. If a '''very''' large pit object is modelled which requires connection to more 2D cell than the maximum a '''SX''' boundary can be manually specified in a 2d_bc layer, this gives the user control over the cells connected to the pit. | ||
− | + | ||
− | |||
− | |||
|prelink=[[TUFLOW_Message_2214|Message 2214]] | |prelink=[[TUFLOW_Message_2214|Message 2214]] | ||
|uplink=[[2xxx_TUFLOW_Messages|2xxx Messages]] | |uplink=[[2xxx_TUFLOW_Messages|2xxx Messages]] | ||
|nextlink=[[TUFLOW_Message_2216|Message 2216]] | |nextlink=[[TUFLOW_Message_2216|Message 2216]] | ||
}} | }} |
Revision as of 14:25, 6 July 2022
TUFLOW Message
WARNING 2215 - Exceeded limit of 2D cells connected to 1D pit object.
Alternate Message
NA
Message Type
WARNING
Description
A 1D pit object can be connected to a maximum of 10 2D cells.
Suggestions
Change number of cells pit is connected to using the Conn_No attribute in the 1d_nwk layer. If a very large pit object is modelled which requires connection to more 2D cell than the maximum a SX boundary can be manually specified in a 2d_bc layer, this gives the user control over the cells connected to the pit.
Up |
---|
2xxx Messages |