Difference between revisions of "TUFLOW Message 2306"

From Tuflow
Jump to navigation Jump to search
Line 5: Line 5:
 
|message_desc=Occurs when a WrF (Weir calibration factor for upstream controlled weir flow) of zero has been found. For "<tt><font color="blue">Wetting and Drying </font><font color="red">== </font><font color="black">ON Method B</font></tt>" which has been the default method since 2012-05 a non zero WrF must be specified.  For "<tt><font color="blue">Wetting and Drying </font><font color="red">== </font><font color="black">ON</font></tt>" or "<tt><font color="blue">Defaults </font><font color="red">== </font><font color="black">Pre 2012</font></tt>" a zero value could be used to locally turn off the weir function.
 
|message_desc=Occurs when a WrF (Weir calibration factor for upstream controlled weir flow) of zero has been found. For "<tt><font color="blue">Wetting and Drying </font><font color="red">== </font><font color="black">ON Method B</font></tt>" which has been the default method since 2012-05 a non zero WrF must be specified.  For "<tt><font color="blue">Wetting and Drying </font><font color="red">== </font><font color="black">ON</font></tt>" or "<tt><font color="blue">Defaults </font><font color="red">== </font><font color="black">Pre 2012</font></tt>" a zero value could be used to locally turn off the weir function.
 
|suggestions=Check for zero values that may have been inadvertently applied using one or a combination of the following commands: <tt><font color="blue">Read GIS WrF </font><font color="red">==</font>, <font color="blue">Set WrF </font><font color="red">==</font>, <font color="blue">Read RowCol WrF </font><font color="red">==</font></tt>.
 
|suggestions=Check for zero values that may have been inadvertently applied using one or a combination of the following commands: <tt><font color="blue">Read GIS WrF </font><font color="red">==</font>, <font color="blue">Set WrF </font><font color="red">==</font>, <font color="blue">Read RowCol WrF </font><font color="red">==</font></tt>.
|discussion_page=* [[Talk:TUFLOW Message 2306|Discuss Message 2306]]
+
 
|link3=''
 
|link4=''
 
 
|prelink=[[TUFLOW_Message_2305|Message 2305]]
 
|prelink=[[TUFLOW_Message_2305|Message 2305]]
 
|uplink=[[2xxx_TUFLOW_Messages|2xxx Messages]]
 
|uplink=[[2xxx_TUFLOW_Messages|2xxx Messages]]
 
|nextlink=[[TUFLOW_Message_2308|Message 2308]]
 
|nextlink=[[TUFLOW_Message_2308|Message 2308]]
 
}}
 
}}

Revision as of 16:26, 6 July 2022

TUFLOW Message
ERROR 2306 - WrF value must be greater than zero.

Alternate Message
NA

Message Type
ERROR

Description
Occurs when a WrF (Weir calibration factor for upstream controlled weir flow) of zero has been found. For "Wetting and Drying == ON Method B" which has been the default method since 2012-05 a non zero WrF must be specified. For "Wetting and Drying == ON" or "Defaults == Pre 2012" a zero value could be used to locally turn off the weir function.

Suggestions
Check for zero values that may have been inadvertently applied using one or a combination of the following commands: Read GIS WrF ==, Set WrF ==, Read RowCol WrF ==.