TUFLOW Message 2304: Difference between revisions

From Tuflow
Jump to navigation Jump to search
Content deleted Content added
No edit summary
No edit summary
Line 5: Line 5:
|message_desc= No 1D node was found connected to variable Z shape 1D trigger.
|message_desc= No 1D node was found connected to variable Z shape 1D trigger.
|suggestions= Check that the trigger location is specified in the Trigger_1 (and/or Trigger_2) attribute, and the trigger point is snapped to a 1D node or a channel end. Note that this functionality is currently only available in TUFLOW 1D ESTRY engine.
|suggestions= Check that the trigger location is specified in the Trigger_1 (and/or Trigger_2) attribute, and the trigger point is snapped to a 1D node or a channel end. Note that this functionality is currently only available in TUFLOW 1D ESTRY engine.

|discussion_page=* [[Talk:TUFLOW Message 2304|Discuss Message 2304]]
|link3=''
|link4=''
|prelink=[[TUFLOW_Message_2302|Message 2302]]
|prelink=[[TUFLOW_Message_2302|Message 2302]]
|uplink=[[2xxx_TUFLOW_Messages|2xxx Messages]]
|uplink=[[2xxx_TUFLOW_Messages|2xxx Messages]]

Revision as of 16:27, 6 July 2022

TUFLOW Message
ERROR 2304 - Could not find 1D Node at Variable Z Trigger for Variable Z Shape.

Alternate Message
NA

Message Type
ERROR

Description
No 1D node was found connected to variable Z shape 1D trigger.

Suggestions
Check that the trigger location is specified in the Trigger_1 (and/or Trigger_2) attribute, and the trigger point is snapped to a 1D node or a channel end. Note that this functionality is currently only available in TUFLOW 1D ESTRY engine.


Up
2xxx Messages