{{TUFLOW_Message | {{TUFLOW_Message | ||
− | |tuflow_message=ERROR 2080 - <font color=" | + | |tuflow_message=ERROR 2080 - <font color="black"><tt>Bed Resistance Cell Sides </tt></font><font color="black"><tt>== </tt></font><font color="black"><tt>INTERROGATE </tt></font> must be used with <font color="black"><tt>Inside Region </tt></font><font color="black"><tt>== </tt></font><font color="black"><tt>Method B</tt></font> |
|alt_msg=NA | |alt_msg=NA | ||
|type=[[ERROR]] | |type=[[ERROR]] |
Revision as of 09:55, 18 July 2022
TUFLOW Message
ERROR 2080 - Bed Resistance Cell Sides == INTERROGATE must be used with Inside Region == Method B
Alternate Message
NA
Message Type
ERROR
Description
Bed Resistance Cell Sides == INTERROGATE (.tcf) must be used with Inside Region == Method B (.tcf). Both of these are defaults. TUFLOW inspects the bed resitance from GIS layers (Read GIS Mat). The approach for Bed Resistance prior to 2007-07 was average M. Valid options for Bed Resistance Cell Sides == AVERAGE M or AVERAGE n or MAXIMUM n or INTERROGATE
Suggestions
This error should only occur if the default Inside Region == Method B is overwritten, Method B is vastly quicker the Method A and testing shows identical results.