− | |tuflow_message=WARNING 1100 - Structure crest/invert is below bed of primary upstream channel | + | |tuflow_message=WARNING 1100 - Structure "a" crest/invert is below bed of primary upstream channel "b". |
− | |alt_msg= | + | |alt_msg= WARNING 1100 - Structure "a" crest/invert is below bed of primary downstream channel "b". |
|type=[[WARNING]] | |type=[[WARNING]] | ||
− | |message_desc=The WARNING is issued where a 1D structure’s invert/bed lies below the bed of the primary upstream and/or downstream channel. | + | |message_desc=The WARNING is issued where a 1D structure’s invert/bed lies below the invert/bed of the primary upstream and/or downstream channel. |
|suggestions= For Build 2013-12-AB onwards, if this WARNING is issued, a review of the 1D topography and structure invert/dimensions is recommended. For Build 2013-12-AA, the issuing of this warning is incorrect and has no effect on the results. | |suggestions= For Build 2013-12-AB onwards, if this WARNING is issued, a review of the 1D topography and structure invert/dimensions is recommended. For Build 2013-12-AA, the issuing of this warning is incorrect and has no effect on the results. | ||
Revision as of 16:26, 27 July 2022
TUFLOW Message
WARNING 1100 - Structure "a" crest/invert is below bed of primary upstream channel "b".
Alternate Message
WARNING 1100 - Structure "a" crest/invert is below bed of primary downstream channel "b".
Message Type
WARNING
Description
The WARNING is issued where a 1D structure’s invert/bed lies below the invert/bed of the primary upstream and/or downstream channel.
Suggestions
For Build 2013-12-AB onwards, if this WARNING is issued, a review of the 1D topography and structure invert/dimensions is recommended. For Build 2013-12-AA, the issuing of this warning is incorrect and has no effect on the results.