Difference between revisions of "TUFLOW Message 3546"
Jump to navigation
Jump to search
(Created page with "{{TUFLOW_Message |tuflow_message=ERROR 3546 - |type=ERROR WARNING |alt_msg=WARNING 3546 - |message_desc= If SGS Materials are on in combination with depth varying Ma...") |
|||
Line 1: | Line 1: | ||
{{TUFLOW_Message | {{TUFLOW_Message | ||
− | |tuflow_message=ERROR 3546 - | + | |tuflow_message=ERROR 3546 - SGS Materials is not supported in this build for models with depth varying Mannings n. |
|type=[[ERROR]] [[WARNING]] | |type=[[ERROR]] [[WARNING]] | ||
− | |alt_msg=WARNING 3546 - | + | |alt_msg=WARNING 3546 - The SGS Materials methodology has changed for the 2022 TUFLOW release and changes in results will occur. |
|message_desc= If SGS Materials are on in combination with depth varying Manning’s n value error is issued and the simulation stops. If SGS Materials is enabled without depth varying Manning’s n values warning is issued. | |message_desc= If SGS Materials are on in combination with depth varying Manning’s n value error is issued and the simulation stops. If SGS Materials is enabled without depth varying Manning’s n values warning is issued. | ||
− | |suggestions=Turn off SGS materials if depth varying Manning’s n is used. Check the use of SGS materials is intentional when depth varying Manning’s n is not used. | + | |suggestions=Turn off SGS materials if depth varying Manning’s n is used. Check the use of SGS materials is intentional when depth varying Manning’s n is not used and review results. |
|prelink=[[TUFLOW_Message_3543|Message 3543]] | |prelink=[[TUFLOW_Message_3543|Message 3543]] |
Revision as of 14:27, 14 October 2022
TUFLOW Message
ERROR 3546 - SGS Materials is not supported in this build for models with depth varying Mannings n.
Alternate Message
WARNING 3546 - The SGS Materials methodology has changed for the 2022 TUFLOW release and changes in results will occur.
Description
If SGS Materials are on in combination with depth varying Manning’s n value error is issued and the simulation stops. If SGS Materials is enabled without depth varying Manning’s n values warning is issued.
Suggestions
Turn off SGS materials if depth varying Manning’s n is used. Check the use of SGS materials is intentional when depth varying Manning’s n is not used and review results.
Up |
---|