TUFLOW 2D Hydraulic Structures: Difference between revisions

Content deleted Content added
No edit summary
Line 239:
 
== How to best convert flow constriction data (2d_fc or 2d_fcsh) into newer formats (2d_lfcsh or 2d_bg)? ==
The form loss parameters can be transferred from the flow constriction (2d_fc or 2d_fcsh) to the first layer of the layered flow constriction (2d_lfcsh) or pier layer of the 2d_bg. Definition of the remaining form loss and blockage layer inputs should follow the guidance outlined in <u>[[TUFLOW_2D_Hydraulic_Structures_draftTUFLOW_2D_Hydraulic_Structures#2D_Layered_Flow_Constriction_.282d_lfcsh.29 | 2D Layered Flow Constriction]]</u> and <u>[[TUFLOW_2D_Hydraulic_Structures_draftTUFLOW_2D_Hydraulic_Structures#2D_BG_Shape_.282d_bg.29 | 2D BG Shape]]</u> paragraphs.<br>
When using floating pontoon (type FD in the 2d_fc or 2d_fcsh) different setup might need to be used for different events. For large events when floating pontoon becomes fixed at the top of the supporting piles, standard 2d_lfcsh setup can be used. Smaller events when the pontoon is floating at different heights might require more sensitivity testing of the structure parameters to find out a setup the matches the reality as close as possible.<br>
<br>