TUFLOW Message 1178: Difference between revisions
No edit summary |
No edit summary |
||
| Line 4: | Line 4: | ||
ERROR 1178 - Reading 1D network layer with extended attributes. Check 1d_nwk layer has correct attributes. Use "Read GIS Network Extended Off == " to use standard attributes. |
ERROR 1178 - Reading 1D network layer with extended attributes. Check 1d_nwk layer has correct attributes. Use "Read GIS Network Extended Off == " to use standard attributes. |
||
|type=[[ERROR]] |
|type=[[ERROR]] |
||
|message_desc=An error has occurred whilst reading 1d network data (1d_nwk). This may occur if the attribute types in the file do not match what TUFLOW is expecting for a 1d_nwk command. |
|message_desc=An error has occurred whilst reading 1d network data (1d_nwk). This may occur if the attribute types in the file do not match what TUFLOW is expecting for a 1d_nwk command.<br> |
||
It can also occur if ten or more extended attributes are used, omitting fields from the 1d_nwke layer. |
|||
|suggestions= Always use an empty 1d_nwk template file as the GIS entry for 1d_nwk inputs. DO NOT create empty 1d_nwk template files mannually yourself. Use either TCF command, <tt><font color="blue">Write Empty MI Files </font><font color="red">== </font></tt> or <tt><font color="blue">Write Empty SHP Files </font><font color="red">== </font></tt> to create these template files. Also, ensure the layer has the correct attributes and ensure that the <tt><font color="blue">Read GIS Network </font><font color="red">== </font></tt> command is only used for network data, not 1D boundary or table links. |
|suggestions= Always use an empty 1d_nwk template file as the GIS entry for 1d_nwk inputs. DO NOT create empty 1d_nwk template files mannually yourself. Use either TCF command, <tt><font color="blue">Write Empty MI Files </font><font color="red">== </font></tt> or <tt><font color="blue">Write Empty SHP Files </font><font color="red">== </font></tt> to create these template files. Also, ensure the layer has the correct attributes and ensure that the <tt><font color="blue">Read GIS Network </font><font color="red">== </font></tt> command is only used for network data, not 1D boundary or table links.<br> |
||
If ten or more extended attributes are used omitting fields from 1d_nwke layer, specify <font color="blue"><tt>Read GIS Network Extended Off </tt></font> command instead. |
|||
|prelink=[[TUFLOW_Message_1177|Message 1177]] |
|prelink=[[TUFLOW_Message_1177|Message 1177]] |
||
Revision as of 10:34, 22 December 2022
TUFLOW Message
ERROR 1178 - Reading channel network data. Check 1d_nwk layer has correct attributes.
Alternate Message
ERROR 1178 - Reading 1D network layer. Check 1d_nwk layer has correct attributes.
ERROR 1178 - Reading 1D network layer with extended attributes. Check 1d_nwk layer has correct attributes. Use "Read GIS Network Extended Off == " to use standard attributes.
Message Type
ERROR
Description
An error has occurred whilst reading 1d network data (1d_nwk). This may occur if the attribute types in the file do not match what TUFLOW is expecting for a 1d_nwk command.
It can also occur if ten or more extended attributes are used, omitting fields from the 1d_nwke layer.
Suggestions
Always use an empty 1d_nwk template file as the GIS entry for 1d_nwk inputs. DO NOT create empty 1d_nwk template files mannually yourself. Use either TCF command, Write Empty MI Files == or Write Empty SHP Files == to create these template files. Also, ensure the layer has the correct attributes and ensure that the Read GIS Network == command is only used for network data, not 1D boundary or table links.
If ten or more extended attributes are used omitting fields from 1d_nwke layer, specify Read GIS Network Extended Off command instead.
| Up |
|---|