Difference between revisions of "TUFLOW Message 1114"
Jump to navigation
Jump to search
Line 6: | Line 6: | ||
|suggestions=For Ogee Weir (WO) channel, the absolute difference between the 1d_nwk attributes "US_Invert" and "DS_Invert" is used to set the height of the weir above its sill. Check these attribute and make sure P is correctly specified. | |suggestions=For Ogee Weir (WO) channel, the absolute difference between the 1d_nwk attributes "US_Invert" and "DS_Invert" is used to set the height of the weir above its sill. Check these attribute and make sure P is correctly specified. | ||
− | |||
|uplink=[[1xxx_TUFLOW_Messages|1xxx Messages]] | |uplink=[[1xxx_TUFLOW_Messages|1xxx Messages]] | ||
− | |||
}} | }} |
Latest revision as of 15:16, 22 December 2022
TUFLOW Message
ERROR 1114 - P for Ogee Weir (WO) channel is invalid: 0. Check US_Invert and DS_Invert attributes.
Alternate Message
NA
Message Type
ERROR
Description
The height of the weir above its sill (P) for Ogee Weir (WO) channel is 0.
Suggestions
For Ogee Weir (WO) channel, the absolute difference between the 1d_nwk attributes "US_Invert" and "DS_Invert" is used to set the height of the weir above its sill. Check these attribute and make sure P is correctly specified.
Up |
---|
1xxx Messages |