TUFLOW Message 1123: Difference between revisions
No edit summary |
No edit summary |
||
Line 8: | Line 8: | ||
[[File:Error 1123.jpeg|800px]] |
[[File:Error 1123.jpeg|800px]] |
||
|prelink=[[TUFLOW_Message_1122|Message 1122]] |
|||
|uplink=[[1xxx_TUFLOW_Messages|1xxx Messages]] |
|uplink=[[1xxx_TUFLOW_Messages|1xxx Messages]] |
||
|nextlink=[[TUFLOW_Message_1124|Message 1124]] |
|||
}} |
}} |
Latest revision as of 15:19, 22 December 2022
TUFLOW Message
ERROR 1123 - More than one cross-section line of same priority for channel
Alternate Message
NA
Message Type
ERROR
Description
Multiple cross-sections with the same priority have been found for channel. Mid channel cross-sections have higher priority than end cross-sections and will prevail. But if multiple mid channel cross-sections are found TUFLOW will give Error 1123.
Suggestions
Check channel and cross-section configuration, remove unwanted cross-section.
If using end cross-sections ensure that the end of the 1d_nwk layer is snapped to a vertex on the cross-section. If this is not the case the cross-section may be treated as a mid cross-section. An example of where this may occur is shown in the schematic below.