Difference between revisions of "TUFLOW Message 1261"
Jump to navigation
Jump to search
Line 6: | Line 6: | ||
|suggestions=Assign a valid Manning's n value for channel. If material values are defined in the XZ cross-section ("M" flag), the n_or_n_F attribute in the 1d_nwk is a multiplication factor and should be set to 1 (this may be adjusted as part of the calibration process). | |suggestions=Assign a valid Manning's n value for channel. If material values are defined in the XZ cross-section ("M" flag), the n_or_n_F attribute in the 1d_nwk is a multiplication factor and should be set to 1 (this may be adjusted as part of the calibration process). | ||
− | + | ||
|uplink=[[1xxx_TUFLOW_Messages|1xxx Messages]] | |uplink=[[1xxx_TUFLOW_Messages|1xxx Messages]] | ||
− | |||
}} | }} |
Latest revision as of 16:00, 22 December 2022
TUFLOW Message
ERROR 1261 - Invalid Manning's n value of ",a," assigned to channel
Alternate Message
NA
Message Type
ERROR
Description
Invalid Manning's n value assigned to channel, this will occur for a 0 or negative Manning's n value.
Suggestions
Assign a valid Manning's n value for channel. If material values are defined in the XZ cross-section ("M" flag), the n_or_n_F attribute in the 1d_nwk is a multiplication factor and should be set to 1 (this may be adjusted as part of the calibration process).
Up |
---|
1xxx Messages |