TUFLOW Message
ERROR 1394 - No external 1D scheme node linked or snapped to Node or invalid attribute value.

Alternate Message
NA

Message Type
ERROR

Description
A TUFLOW 1D (ESTRY) node could not be linked to an external 1D scheme node, or an attribute value is incorrect.

Suggestions
Check that the external 1D node is snapped to the TUFLOW node. Also make sure the external 1D nodes are being read in by TUFLOW using commands such as "Read GIS ISIS Network" or "Read GIS ISIS Nodes".

The other possibility is one of the attribute values is not correct (eg. if using a X1DQ link, this has been incorrectly entered).