TUFLOW Message 1423: Difference between revisions

From Tuflow
Jump to navigation Jump to search
Content deleted Content added
No edit summary
No edit summary
Line 6: Line 6:
|suggestions=Consider connection by upstream or downstream end of the channel instead. Virtual pits need to be read in before 1d_nwk if they are discharging into 1D channels.
|suggestions=Consider connection by upstream or downstream end of the channel instead. Virtual pits need to be read in before 1d_nwk if they are discharging into 1D channels.


|prelink=[[TUFLOW_Message_1422|Message 1422]]
|uplink=[[1xxx_TUFLOW_Messages|1xxx Messages]]
|uplink=[[1xxx_TUFLOW_Messages|1xxx Messages]]
|nextlink=[[TUFLOW_Message_1424|Message 1424]]
}}
}}

Revision as of 10:42, 23 December 2022

TUFLOW Message
ERROR 1423 - Virtual Pit occurs at the same location as a user defined node, manhole or a pit IDs: <channel ids>

Alternate Message
N/A

Message Type
ERROR

Description
Virtual Pit outlet cannot be connected to the same location as a user defined node, manhole or a pit.

Suggestions
Consider connection by upstream or downstream end of the channel instead. Virtual pits need to be read in before 1d_nwk if they are discharging into 1D channels.


Up
1xxx Messages