TUFLOW Message
CHECK 1424 - Pit "a" width calculated as no. of pits [b] x 1d_pit width [c] x pit database width [d] - Total width = "e"

Alternate Message
N/A

Message Type
CHECK

Description
The width of the virtual pit used to connect 2D cells is determined by multiplying the number of pits by the pit width GIS attribute and by the width in the pit inlet database. The multiplication of the GIS width attribute and the width in the pit inlet database may not be intended by the modeller and should be checked for correctness.

Suggestions
Check that the total width is correct. If not, change one of the width attribute in GIS or the width in the pit inlet database to a multiplier value of 1.0.